![]() |
|
|
|
|
Latest New Product News from Fluke Corp.
Test Tools wirelessly connect multiple measurement modules.Fluke Corp. Everett, WA 98203Mar 29, 2013 Based on CAT III 1,000 V/CAT IV 600 V multimeter, CNX Wireless System connects multiple measurement modules and sends simultaneous readings to master device up to 20 m away. Modules, which include AC Voltage, AC Current Clamp, iFlex AC Current Clamp, and K-Type Temperature units, can take live measurements or log up to 65,000 sets of data. Logged data can be saved to computer in .csv format. With system, users can place modules in hazardous areas and watch readings from safe distance. ![]() Dry Block Calibrator conforms to EURAMET cg-13 guidelines.Fluke Corp. Everett, WA 98203Mar 21, 2013 Featuring -95 to 140°C temperature range with ±0.015°C stability, 9190A Ultra-Cool Field Metrology Well covers coldest and warmest temperatures required in pharmaceutical, biomedical, and food processing applications that demand strict quality control and regulatory compliance including on-location validation/calibration of RTDs, thermocouples, and thermometers. Unit with process option features 4–20 mA connectors, reference thermometer input, and 4-wire PRT/RTD input with accuracy of ±0.02°C. ![]() Current Loop Calibrator features HART communications.Fluke Corp. Everett, WA 98203Mar 01, 2013 Providing 0.01% reading accuracy, Fluke® 709H minimizes time it takes to measure or source, voltage or current, and power up loop. Unit features Quick-Set rotary encoder knob, 2-wire connection, and built-in selectable 250 Ω resistor to tune loop for HART communications. In communicator mode, technicians can read basic device information, perform diagnostic tests, and trim calibration on most HART-enabled transmitters. Ramping and auto-stepping enable technicians to perform tests remotely. ![]() Visual IR Thermometer measures temperatures from 14-482°F.Fluke Corp. Everett, WA 98203Jan 09, 2013 Filling gap between thermometers and thermal imagers, Fluke® VT02 combines visual insight of thermal imager, visual images of digital camera, and point-and-shoot convenience of infrared thermometer. Troubleshooting camera with infrared heat map will display and save images as full visual, full infrared, or 3 blended modes of 25, 50, and 75%. Images are saved to micro-SD card and can be imported into SmartView® software for analysis and reporting. ![]() Handheld Oscilloscope achieves 500 MHz at 5 GSPS sample rate.Fluke Corp. Everett, WA 98203Nov 28, 2012 Intended for electronic troubleshooters, Fluke® 190 Series II 500 MHz ScopeMeter® Test Tool delivers scope with bandwidth and resolution to capture any signal while in field. Two-channel 190-502 model, with bandwidth from 60, 100, 200, and 500 MHz, supports 5 GSPS sample rate for accuracy and clarity of shape and amplitude of unknown waveform phenomena. ScopeRecord™, TrendPlot™, advanced triggering, and automatic measurements functions are included. Wireless Multimeter System enables reading from safe distance.Fluke Corp. Everett, WA 98203Nov 23, 2012 Designed to wirelessly connect multiple electrical and temperature measurement modules, Fluke® CNX Wireless System sends simultaneous readings to master device up to 20 m away. Unit is based on CAT III 1000 V / CAT IV 600 V multimeter with screen that displays its readings along with live readings from up to 3 other measurement modules. For more complex troubleshooting, users can view live measurements from up to 10 modules simultaneously on computer equipped with CNX PC Adapter. Process Calibrator offers simultaneous sourcing, measurement.Fluke Corp. Everett, WA 98203Nov 09, 2012 With isolated measurement channel, 7526A can calibrate RTD and thermocouple readouts, pressure gauges, temperature and pressure transmitters, digital process simulators, data loggers, and multimeters. Benchtop unit simulates and measures 9 RTD and 13 thermocouple types, can measure pressure to within 0.008% of reading, sources and measures 0–100 Vdc to within 0.004% of reading, sources DC current from 0–100 mA, measures DC current to within 0.01% from 0–50 mA, and supplies 24 Vdc loop power. ![]() Power Quality and Energy Analyzer captures 400 Hz measurements.Fluke Corp. Everett, WA 98203Oct 03, 2012 Designed for avionics and defense technicians, Fluke® 437 Series II can record up to 150 parameters on 4 phases simultaneously. Unit utilizes Unified Power Management algorithm to measure and quantify energy losses due to harmonics and unbalance issues, allowing user to pinpoint origin of energy waste. PowerWave capture system displays waveforms and half cycle RMS voltage and current values in full detail to measure interactions during switching operations to prevent motor/drive/load mismatches. ![]() Asset Management Software manages calibration test equipment.Fluke Corp. Everett, WA 98203Sep 26, 2012 Integrated with MET/CAL® Calibration Management Software, MET/TEAM Test Equipment Asset Management Software allows users to manage all aspects of calibration operation. Browser-based program helps users maintain compliance with regulatory standards, schedule maintenance events, perform batch receiving, create automated email alerts, and track assets through lab. Calibration professionals can also create and print calibration reports, maintain audit trail, and track customer and vendor information. Digital Multimeter meets global intrinsically safe standards.Fluke Corp. Everett, WA 98203Sep 18, 2012 Housed in sealed, IP67-rated case, Fluke® 28 II EX can perform measurements both inside and outside hazardous zones, and can withstand 8,000 V spikes caused by load switching and faults on industrial circuits. Unit features 20,000 count display and true-rms AC voltage and current for accurate measurement on non-linear signals. Measuring up to 1,000 V and 10 A AC and DC as well as temperature from -328 to 1,994ºF, DMM is suited for petroleum, chemical, and pharmaceutical facilities. Click below for more Product News from Fluke Corp. Next News Stories Other Company News From Fluke Corp.
Apr 17, 2013 Fluke Thermal Imagers Now Display Simultaneous Electrical and Thermal ReadingsOct 11, 2012 New Fluke Ti105 and TiR105 Thermal Imagers Deliver Extraordinary Performance from an Everyday ImagerDec 20, 2010 New Fluke Newsletter Helps Electricians, Engineers and Maintenance Techs Boost Reliability and Make Work EasierDec 02, 2010 Fluke 27 II and 28 II Industrial Multimeters Gain Approval from Mine Safety and Health AdministrationNov 22, 2010 Students Win as Fluke Presents Five Schools with Grants of Industrial Process Test GearOct 14, 2010 Fluke Names Jeff C. Gust as Chief Corporate MetrologistSep 28, 2010 Fluke Introduces Industry's Most Advanced Family of Clamp Meters, Engineered for the Most Demanding ConditionsSep 22, 2010 Fluke Announces New Grant Program for Educators and Students in Industrial Process Control TechnologyDec 15, 2009 Fluke 1750 Three-Phase Power RecorderNov 05, 2008 New Fluke Extreme Cases by Pelican Protect Fluke Test Tools in the Toughest Work EnvironmentsOct 29, 2008 Contractor and TV Personality Chip Wade Teams with Fluke to Teach Thermal Imaging Techniques for Building InspectorsOct 21, 2008 Fluke Thermal Imagers Now Include Robust In-Box Training to Help Users Get Up and Running QuicklyOct 13, 2008 Fluke Introduces New Silver Instrument CarePlan to Provide Extended Warranty Coverage for Test ToolsSep 22, 2008 Fluke Introduces New Software Capabilities for Fluke 287 and 289 True-RMS Logging MultimetersDec 13, 2007 Kit Combines Fluke 289 True-rms Logging Multimeter and FlukeView® Forms Software for Predictive Maintenance TasksDec 04, 2007 Fluke Biomedical Releases 35080M199XRAY Medical ScopeMeter/kVp Divider Kit Instructional videoNov 29, 2007 Fluke Offering Educational Programs Opportunity to Receive Donation of New High-Performance 289 MultimetersNov 16, 2007 Condition Monitoring with Fluke's Money-Saving Logging Multimeter and Software Combo KitFeb 20, 2007 Fluke Corporation Acquires DH Instruments, Inc.Jan 17, 2007 New "MET-101" and "MET-301" Training Courses from Fluke Provide Hands-on Instruction in Basic and Advanced Metrology ConceptsOct 10, 2006 Fluke Introduces New Family of DMMs with Special Features for Commercial Electricians, HVAC/R Professionals and MoreJul 20, 2006 Fluke Updates Electrical Measurement Safety Education Video with Latest NFPA 70E InformationMar 17, 2006 Fluke Receives TDAP Certification from VDEMar 10, 2006 Fluke Announces Grand Prize Winners in Drive-A-Jeep SweepstakesFeb 24, 2006 Fluke Announces New 'Metrology for Cal Lab Personnel' Training CourseSep 26, 2005 Infrared Solutions to be acquired by electronics manufacturer Fluke Electronics CorporationSep 07, 2005 Fluke adds three new learning modules to its Education Partnership Program |
![]() |
||||||||||||||||
| Home | My ThomasNet News® | Industry Market Trends® | Submit Release | Advertise | Contact News | About Us |
![]() |
|
Brought to you by Thomasnet.com
Browse ThomasNet Directory |