![]() |
|
|
|
|
Latest New Product News from Endress + Hauser Inc.
![]() Real-Time Cell Density Sensor leverages NIR optical absorption.Endress + Hauser Inc. Greenwood, IN 46143Apr 09, 2013 Supplied in 316L stainless steel body with sapphire windows, hygienic and non-intrusive OUSBT66 is designed for in-situ cell production optimization in life science processes, fermentation biomass measurement, and algae growth monitoring for biofuel production. Measuring head, which contains LED light source and optical sensor, is hermetically sealed. Light is filtered to 880 nm on detector side of sensor, allowing direct correlation of cell density in process by receiving sensor. ![]() Point Level Switches support safety applications up to SIL3.Endress + Hauser Inc. Greenwood, IN 46143Dec 04, 2012 Liquiphant FailSafe FTL8x series offers 2 relay outputs, 4–20 mA output that connects to failsafe switching unit with 2-channel output, safety contacts, and safety locking function. Built-in diagnostics monitor tuning fork-type sensor for damage, corrosion, material buildup, and mechanical blocking, and switches support min and max level detection in liquids from -76 to +536°F, at pressures up to 1,450 psi, viscosity up to 10,000 mPa-s, and densities from 0.4–2.0 g/cm³. ![]() Ultrasonic Sensor measures liquid-solid interfaces in tanks.Endress + Hauser Inc. Greenwood, IN 46143Nov 26, 2012 Turbimax CUS71D ultrasonic interface sensor suits water, wastewater, and chemical processes where suspensions are separated into liquid and solid components by sedimentation. Used with Liquiline M CM44x transmitters, product can detect interface level at distances of 1-32 ft with maximum error of 1.3 in. Immersion sensor operates in process temperatures from 34-122ºF and pressures up to 87 psi. It installs in open basins, channels, and tanks with stainless steel or PVC mounting hardware. ![]() Coriolis Flowmeter features corrosion-resistant design.Endress + Hauser Inc. Greenwood, IN 46143Oct 22, 2012 Immune to external disturbances, Proline Promass 83O/84O simultaneously measure mass flow, fluid density, and temperature and remain stable despite changing process conditions. All materials that can come in contact with gasses and fluids are manufactured from super duplex stainless steel with 25% Cr, and external design is of T316L stainless steel. Resistant to corrosion, products handle pressures to 3,742 psi and process temperatures from -40 to +392°F. ![]() Optical Absorption Sensor serves liquid measurement applications.Endress + Hauser Inc. Greenwood, IN 46143Oct 08, 2012 Measuring optical absorbance by process fluid, OUSAF11 is suited for loss and interface detection, measuring suspended solids and turbidity, as well as detecting phase separations and product loss. Sensor emits light visible and NIR regions, and absorption by process fluid is determined using optical sensor mounted in sensor head. Sensor is available in immersion model for open tanks and basins or insertion model with Tri-Clamp or Varivent connections that meet 3A Sanitary Standards. ![]() Electromagnetic Flowmeter offers cellphone access.Endress + Hauser Inc. Greenwood, IN 46143Sep 24, 2012 Featuring GSM/GPRS cellphone wireless capability for data communications and configuration, battery-powered Promag L800 is suited for flow measurement in remote water and wastewater systems. Once configured, operator at central control room can receive alarms, query totalizer readings, and change flowmeter configuration. Available in sizes from 2–24 in., Promag L800 operates at pressures to 232 psi with maximum flow rate of 33 ft/sec and accuracy of 0.5% of reading. ![]() Differential Pressure Transmitter eliminates capillary tubes.Endress + Hauser Inc. Greenwood, IN 46143Sep 05, 2012 Using 2 pressure sensor modules connected electronically to single transmitter, Deltabar FMD72 eliminates impulse lines or capillaries and related issues such as leaks, condensation, icing, and plugging. One sensor measures hydrostatic pressure, while second sensor measures head pressure, and transmitter calculates differential pressure. Operating in process temperatures from -40 to 257ºF, sensors offer 0.075% accuracy over measuring range of -15 to 150 psi. Accuracy of entire system is 0.1%. ![]() Coriolis Mass Flow Transmitter supports industry customization.Endress + Hauser Inc. Greenwood, IN 46143Aug 22, 2012 Immune to process and environmental influences, Proline Promass 100 measures mass flow, volume flow, density, viscosity, concentration, and temperature with accuracy up to ±0.05%. Product can be combined with industry-specific sensors, materials, and finishes for use in food, beverage, life sciences, pharmaceutical, chemical, and other industries. All measurements are fully traceable, and seamless system integration is possible via EtherNet/IP and Modbus RS-485 digital communication. ![]() Electromagnetic Flowmeter serves water, wastewater applications.Endress + Hauser Inc. Greenwood, IN 46143Aug 15, 2012 With its drinking water approvals and corrosion protection, Proline Promag L 400 can be installed underwater, underground, and in saline environments. Sensors are available in nominal diameters from 2-90 in., and Ethernet port and built-in webserver facilitate data access and configuration via any Web browser. Along with accuracy of 0.2% of range, flowmeter has on-board HistoROM(TM) system that stores all sensor, transmitter, and totalizer data; no data is lost if power is removed. ![]() Hygienic Pressure Transmitters work with gas, steam, liquids.Endress + Hauser Inc. Greenwood, IN 46143Jul 30, 2012 Available with ceramic or metal process isolating diaphragm seals, Cerabar M PMC51 and PMP51 are suitable for absolute and gauge pressure measurements in gases, steams, or liquids as well as level, volume, and mass measurements in liquids. Standard accuracy is 0.15% (0.075% optional), and long term stability is 0.1% of upper range limit (URL)/year and 0.25% of URL/5 years. Able to work in temperatures to 752°F or pressures to 6,000 psi, programmable sensors offer multiple output options. Click below for more Product News from Endress + Hauser Inc. Next News Stories Other Company News From Endress + Hauser Inc.
Jun 01, 2013 Endress+Hauser Announces E-Direct Online Instrument StoreMay 20, 2013 Endress+Hauser Announces August Training SchoolsApr 15, 2013 Endress+Hauser Releases White Paper on Instrumentation for Produced WaterMar 24, 2013 Endress+Hauser Announces June Training SchoolsMar 18, 2013 Endress+Hauser Launches New Online Process Instrumentation TrainingMar 06, 2013 Endress+Hauser Signs Vector Controls and Automation Groupas Its Representative in the Gulf Region of U.S.Feb 19, 2013 Endress+Hauser Announces May Training SchoolsFeb 01, 2013 Endress+Hauser Announces April Training SchoolsOct 26, 2012 Endress+Hauser Introduces Operations AppMay 08, 2012 Endress+Hauser and Rockwell Automation Open a New Process Training Unit in Philadelphia, PAFeb 27, 2012 Endress+Hauser Releases White Paper Showing How to Maintain pH SensorsFeb 09, 2012 E+H Publishes White Paper on Using Guided Wave Radar in Steam LoopsSep 28, 2011 Endress+Hauser Announces Instrumentation Package for Wastewater Aeration ControlJun 15, 2011 Endress+Hauser Opens Temperature Instrumentation Manufacturing Plant in U.SFeb 15, 2011 Endress+Hauser Opens Two More Training CentersAug 04, 2010 Endress+Hauser Earns ISO17025 Certification for Laboratory and Field Calibration from A2LAJul 20, 2010 Agrochemical Operation Reduces pH Maintenance Hours by 50%Jun 27, 2010 Endress+Hauser Announces Deltabar M, Cerabar M and Deltapilot M Pressure TransmittersMay 01, 2010 Endress+Hauser Installs WirelessHART Network in Mining Operation's Movable Leach FieldsApr 26, 2010 Endress+Hauser Announces Applicator ToolJun 04, 2009 Endress+Hauser Expands Production in the USJan 26, 2009 New A2LA Accredited Production RigOct 17, 2008 We Are Excited to Announce the Grand Opening of the New Endress+Hauser Gulf Coast Calibration and Service CenterMay 12, 2008 Supporting Your Business Processes with W@M - Life Cycle ManagementSep 20, 2007 New Selection and Sizing Tool Assists in Planning for Instrument NeedsNov 14, 2005 Easier to Use and Many New Features |
![]() |
||||||||||||||||
| Home | My ThomasNet News® | Industry Market Trends® | Submit Release | Advertise | Contact News | About Us |
![]() |
|
Brought to you by Thomasnet.com
Browse ThomasNet Directory |