ThomasNet News Logo
Sign Up | Log In | ThomasNet Home | Promote Your Business
 Journals
Industry Market Trends ®
Fluid & Gas Flow Journal
Machining Journal
Procurement Journal
Tech Trends Journal
 Industry News
Latest New Product News
Association & Government News
 Product News
Adhesives and Sealants
Agricultural and Farming Products
Architectural and Civil Engineering Products
Automatic ID
Chemical Processing and Waste Management
Cleaning Products and Equipment
Communication Systems and Equipment
Computer Hardware and Peripherals
Construction Equipment and Supplies
Controls and Controllers
Display and Presentation Equipment
Electrical Equipment and Systems
Electronic Components and Devices
Explosives, Armaments and Weaponry
Fasteners and Hardware
Fluid and Gas Flow Equipment
Food Processing and Preparation
Green & Clean
Health, Medical and Dental Supplies and Equipment
HVAC
Labels, Tags, Signage and Equipment
Laboratory and Research Supplies and Equipment
Lubricants
Machinery and Machining Tools
Material Handling and Storage
Materials and Material Processing
Mechanical Components and Assemblies
Mechanical Power Transmission
Mining, Oil Drilling & Refining
Mounting and Attaching Products
Non-Industrial Products
Optics and Photonics
Packaging Products & Equipment
Paints and Coatings
Plant Furnishings and Accessories
Portable Tools
Printing and Duplicating Equipment
Retail and Sales Equipment
Robotics
Safety and Security Equipment
Sensors, Monitors and Transducers
Services
Software
Test and Measuring Instruments
Textile Industry Products
Thermal and Heating Equipment
Timers and Clocks
Transportation Industry Products
Vision Systems
Waste Handling Equipment
Welding Equipment and Supplies
 Press Releases
Products in the News
Company News
Mergers & Acquisitions
People in the News
Literature & Websites
 Resources
News Delivery Options
SME
Browse Categories
Browse Companies
Mobile Edition
PR Resources
Licensing
Advertising
Call for Contributors, Guest Writers and Submissions
How to Write an effective Press Release
Trade Associations
AMETEK Test & Calibration Instruments
8600 Somerset Dr.
Largo, FL, 33773

Detailed Contact Information:
Pressure Indicator includes data logger functionality.   Return to story
Company Information:
AMETEK Test & Calibration Instruments
8600 Somerset Dr.
Largo , FL  33773   USA
Phone: 800-527-9999
FAX: 727-539-6882
http://www.chatillon.com
General Information:
Poul Madsen
Denmark
Phone: +45-2030-6470
 
 
Latest New Product News from AMETEK Test & Calibration Instruments
Products or services this company supplies:
 
Click links to find other companies which supply the same products or services.
Materials Testing Systems incorporate intuitive touchscreen.

Materials Testing Systems incorporate intuitive touchscreen.

AMETEK Test & Calibration Instruments    Largo, FL 33773
Jan 10, 2013 Using linear guide technology, pre-loaded ball screws, and software compensation systems to promote precision displacement measurement, CHATILLON® CS225 and CS1100 are, respectively, 225 and 1,124 lbf, single-column machines with 180 and 150 mm throat depths. Both machines, used for tensile, compression, sheer, flexural, or multi-stage testing, feature 8.9 in. industrial-grade touchscreen (IP65) designed for continuous operation by users of all levels in production environment.
Pressure Indicator includes data logger functionality.

Pressure Indicator includes data logger functionality.

AMETEK Test & Calibration Instruments    Largo, FL 33773
Nov 21, 2012 Available in 10 pressure ranges from 15–10,000 psi, JOFRA® IPI Mk II combines ease of analog gauge with accuracy and display of digital calibrator. Portable unit features ±0.05% FS accuracy and is temperature compensated for workshop use or in-process applications. Offered as stand-alone indicator or in 1 of 6 test-ready systems, indicator is ATEX and CSA certified for use in potentially explosive environments such as oil refineries, chemical plants, and offshore platforms.
Loop Signal Calibrator is designed for usability, accuracy.

Loop Signal Calibrator is designed for usability, accuracy.

AMETEK Test & Calibration Instruments    Largo, FL 33773
Oct 10, 2012 Suitable for field and workshop use, JOFRA® CSC101 mA loop calibrator offers 1 µA resolution to meet accuracy demands of sensors and transmitters. Intuitive UI and bright, high-resolution display facilitates use, while step and ramp functions and rotary knob with built-in Enter push function promote functionality. Powered by 6 AAA batteries that provide 40+ hr battery life, this rugged, handheld instrument features fuseless protection against overloads up to 250 Vac.
Handheld Signal Calibrator works with RTDs, thermocouples.

Handheld Signal Calibrator works with RTDs, thermocouples.

AMETEK Test & Calibration Instruments    Largo, FL 33773
Aug 20, 2012 Intended for field calibration and workshop use, JOFRA® CSC201 lets process engineers calibrate 14 types of RTDs and 13 types of thermocouples. Instrument provides ohms, mV, and custom RTD curves and works with pulsed excitation transmitters and PLCs. When used with JOFRA APM external pressure module or JOFRA calibration pump, unit can also measure and calibrate pressure. All functions are displayed on graphical display, and fuseless protection against overloads is rated to 250 Vac.

Materials Testers perform precision displacement measurement.

AMETEK Test & Calibration Instruments    Largo, FL 33773
Mar 21, 2012 Rated at 5 and 2.5 kN, respectively, single-column Lloyd Instrument LS5 and LS2.5 feature linear guide technology, pre-loaded ball screws, and software compensation systems. Both are available with range of grips, fixtures, and extensometers. LS2.5 system has crosshead travel of up to 1,400 mm and crosshead speed range of 0.01-2,032 mm/min, while LS5 has crosshead speed range of 0.01-1,016 mm/min. Load accuracy is ±0.5 down to 1% of load cell value.

Machine Control Software aids specialty contact lens production.

AMETEK Test & Calibration Instruments    Largo, FL 33773
Dec 12, 2011 By incorporating complex algorithms, Optoform® control software MCS v1.29 facilitates production of toric, multifocal, prism, and slab-off contact lens designs. Capabilities also help optimize form and surface finish for existing Optoform asymmetric lathe files and allow for contouring of front and back asymmetric edges for better wearer comfort. Solution works with Sterling FTS® 1000 fast tool servo, which offers peak acceleration of 200 m/sec².
Intrinsically Safe Pressure Calibrators have backlit LCD.

Intrinsically Safe Pressure Calibrators have backlit LCD.

AMETEK Test & Calibration Instruments    Largo, FL 33773
Nov 01, 2011 Delivering laboratory accuracy, JOFRA® HPC550 (single sensor) and HPC552Ex (dual sensor) are suited for use in hazardous oil, gas, petrochemical, and other applications. Both handheld, on-site, field-usable instruments offer user-configurable information display, 15 pressure units, mA input, and percent error calculation. JOFRA HPC552 Ex can handle 2 pressure ranges, and both models feature ATEX/IECEx certification for use in potentially explosive situations.

Handheld Pressure Calibrators feature deadweight accuracy.

AMETEK Test & Calibration Instruments    Largo, FL 33773
May 20, 2011 Compliant with ATEX/IECEx certifications and rated intrinsically safe for potentially hazardous locations, JOFRA® HPC550Ex (single sensor) and HPC552Ex (dual sensor) series are on-site, field-usable instruments with backlit graphical display. Both are temperature compensated from 32-113°F and offer 16 pressure ranges from 0.35-10,000 psi, with FS Absolute, differential, and gauge sensors, and accuracy to ±0.025% of reading and 0.01% FS. Variety of functions and features are standard.

Materials Tester utilizes linear guide technology.

AMETEK Test & Calibration Instruments    Largo, FL 33773
Feb 04, 2011 Available in 500 and 800 mm travel versions, Model LS1 is suited for materials testing applications under 1 kN force. Single-column unit provides high-precision displacement measurement using linear guide technology, pre-loaded ball screws, and advanced software compensation systems. With extended crosshead speed range of 0.01-2,032 mm/min, tester offers load accuracy of ±0.5 down to 1% of load cell value. Wide throat depth of 180 mm provides large working area for sample placement.
Reference Temperature Calibrator ranges from 91 to 1,292°F.

Reference Temperature Calibrator ranges from 91 to 1,292°F.

AMETEK Test & Calibration Instruments    Largo, FL 33773
Mar 24, 2010 Through triple-zone heating technology, JOFRA® RTC-700 provides precise temperature calibration of sensors, regardless of type and format. Dynamic Load Compensation sensor measures temperature in calibrator's insert and provides feedback to active triple-zone system to compensate for temperature differences resulting from testing various sensors. Offering plug-n-play connectivity, dry-block calibrator includes full-color VGA display and USB connection.


Click below for more Product News from AMETEK Test & Calibration Instruments

Next News Stories



Other Company News From AMETEK Test & Calibration Instruments

Nov 22, 2011

Chatillon® Digital Hanging and Crane Scales are the Solution for a Wide Range of Weighing Applications


Apr 09, 2010

JOFRA® AMC 910 Advanced Multi-Purpose Calibrator for High-Precision Signal, Temperature and Pressure Calibration


Jan 15, 2010

BC Group International Now Provides Support for M&G Speed Management Products


Sep 28, 2009

New! - Jofra Handheld Pressure Calibrator


Jul 18, 2008

ATEX Certification for JOFRA Industrial Pressure Indicators






Home  |  My ThomasNet News®  |  Industry Market Trends®  |  Submit Release  |  Advertise  |  Contact News  |  About Us
Brought to you by Thomasnet.com        Browse ThomasNet Directory

Copyright © 2014 Thomas Publishing Company. All Rights Reserved.
Terms of Use - Privacy Policy