V-Cone Steam-Injection Flow Meter Supports Enhanced Oil Recovery (EOR)

Print | 
Email |  Comment   Share  

McCrometer, Inc.
3255 W. Stetson Ave.
Hemet, CA, 92545
USA



Press release date: April 29, 2011

Ideal for Highly Viscous (Heavy) Oil Requiring Thermal Stimulation

Hemet, CA - Upstream oil/gas engineers will find McCrometer's precision V-Cone® Steam-Injection Flow Meter supports enhanced oil recovery (EOR) technologies that produce heavy oil from demanding environments, such as shallow oil sands deposits and other challenging formations.

Featuring unique differential pressure (dP) technology, McCrometer's self-conditioning V-Cone Flow Meter provides superior flow measurement accuracy and repeatability over a broad flow range regardless of fluid dynamics. Accuracy is ±0.5 percent with repeatability of ±0.1 percent over a wide turndown. With virtually no maintenance or recalibration requirements, the V-Cone also operates over a long life with a low cost of ownership.

Steam injection has become an increasingly popular thermal process for third stage oil production. This EOR method is used to restore pressure, reduce viscosity, and improve flow to prolong the life of the oilfield. Steam flooding is used for shallow oil reservoirs with heavy viscous oil. Steam flooding can reach recovery rates of 50-80%. The V-Cone reduces permanent pressure loss by 75% compared to a traditional orifice plate. In addition, steam flooding requires multiple meters to monitor the process that must operate over the life of the field with low maintenance requirements to make the operation cost-effective.

The V-Cone Flow Meter features a rugged no-moving parts design with nothing to foul or break in harsh oil production environments. The contoured shape of the V-Cone's beta edge prevents it from dulling like that of an orifice plate beta edge, eliminating the need for the costly periodic inspection and replacement of plates.

Unlike traditional dP instruments such as orifice plates and venturi tubes, the V-Cone Flow Meter's design is inherently more accurate because the flow conditioning function is built into the design. The meter's centrally located cone interacts with the steam, reshaping the velocity profile to provide a stable signal that increases measurement accuracy.

In steam flow, the pressure difference exhibited between the V-Cone Flow Meter's static line pressure and the low pressure created downstream of the cone is measured via two pressure sensing taps, with one tap placed slightly upstream of the cone and the other located in the downstream face of the cone itself. The pressure difference is then incorporated into a derivation of the Bernoulli equation to determine the flow rate of the steam.

McCrometer's V-Cone Flow Meter with built-in flow conditioning also reduces the upstream/downstream straight pipe run required by Orifice Plates and Venturi Tubes by up to 70 percent. This significant reduction in pipe requirements adds up to materials and installation labor cost savings-especially in crowded retrofit projects where existing (expensive-to-move) equipment already is in place.

About McCrometer
McCrometer's advanced liquid, steam and gas flow measurement solutions solve complex challenges in Municipal/Industrial Water & Wastewater, Oil & Gas, Process Control & Plant, Electric Power Generation, Institutional Facilities and Agriculture. The company's products and systems are found in thousands of installations worldwide. Its products and systems meet many of the world's most demanding industrial, safety and quality standards. Visit us on the web at www.mccrometer.com

Company Contact: Jennifer Kerckhoff, (281) 998-0449
Company Address: 3255 W Stetson Ave, Hemet, CA 92545
Web: http://www.mccrometer.com
Tel: 800-220-2279 Tel: 951-652-6811 Fax: 951-652-3078
Print | 
Email |  Comment   Share  
Contacts: View detailed contact information.


 

Post a comment about this story

Name:
E-mail:
(your e-mail address will not be posted)
Comment title:
Comment:
To submit comment, enter the security code shown below and press 'Post Comment'.
 



 See related product stories
More .....
Don’t hunt for stories like this.
Let Product News Come to You!
Get a Free Subscription
to Product News Alerts.
Edit Story Categories
Start Your Free
Subscription to
Industry Market Trends.
 See more product news in:
Sensors, Monitors and Transducers
Test and Measuring Instruments
 More New Product News from this company:
Direct Mount Flowmeter features direct mount configuration.
Telemetry System supports irrigation applications.
Insertion Flow Meter provides bi-directional measurement.
Electromagnetic Flow Meter supports hot tap installation.
Inline Flow Meter targets water filtration plants.
More ....
 Other News from this company:
McCrometer to Feature FPI Mag(TM) Flow Meter at AWWA ACE12
McCrometer Presents Advanced Offshore Flow Measurement Solutions at OTC 2012
McCrometer Installs New Wet Gas Test Stand to Support Energy Industry R&D Programs
Space-Saving V-Cone Flow Meter Cuts WAG System Installed & Operational Costs
FPI Mag(TM) & V-Cone® Flow Meters Provide Accurate Measurement with Low Maintenance and Life-Cycle Costs
More ....
 Tools for you
Watch Company 
View Company Profile
Company web site
More news from this company
E-Mail Story
Save Story
Search for suppliers of
Flow Gages
Differential Pressure Flowmeters
Flowmeters
Join the forum discussion at:
Tools of the Trade


Home  |  My ThomasNet News®  |  Industry Market Trends  |  Submit Release  |  Advertise  |  Contact News  |  About Us
Brought to you by Thomasnet.com        Browse ThomasNet Directory

Copyright © 2012 Thomas Publishing Company
Terms of Use - Privacy Policy



Error close

Please enter a valid email address