Intelligent dataTaker System Handles All Data Collection

CHESTERLAND OH - CAS DataLoggers has just provided an intelligent data logger for a manufacturer facing stringent environmental regulations requiring them to continuously monitor and manage their effluent disposal. Before effluent is discharged from the facility, it had to be heavily treated in a pre-treatment pool. This particular manufacturer had an existing SCADA system which they wanted to integrate with a data logging solution. They needed a single solution to connect to all their different types of water quality sensors, perform real time calculations, and also to control the addition of chemicals to neutralise the pool effluent.

CAS DataLoggers provided a dataTaker DT80 Universal Input Data Logger which was installed into a waterproof enclosure adjacent to the wastewater treatment pool. Users then connected the data logger via side ports to several different types of sensors permanently installed in the pre-treatment plant measuring water pH, flow, and temperature. Once setup, the standalone DT80 began collecting all the data at user-defined intervals.

Users also programmed the DT80 to calculate (in real time) the exact quantity of caustic soda that needed to be added to neutralize the effluent's acidity before discharge, and then control this addition via relays connected to the logger's programmable digital outputs. Similarly, the DT80 raised alarms to alert engineers whenever effluent pH, temperature or volume exceeded license requirements.

All the real-time data was conveniently monitored via the plant's SCADA system with a Modbus connection using RS485 or Ethernet, and was also useable with the dataTaker's internal web interface. Alternatively, historical data could be periodically downloaded over a network or via a USB memory stick to be reviewed on a PC located elsewhere at the effluent disposal plant. In this way, the dataTaker system allowed personnel to observe the change in water quality at any time from any place.

The DT80 datalogger could be expanded up to 100 channels, featuring universal analog channels for connection to most sensor types. Users could view the data in mimics to get a clear dashboard-style readout and also store as many as 10 million data points in the logger's user-defined memory.

The dataTaker DT80 also included free dEX software with an intuitive graphical interface enabling operators to configure the datalogger, generate trend charts and tables, and retrieve historical data for analysis. The built-in software ran directly from a web browser and could be accessed locally or remotely, including globally over the Internet.

The manufacturer's wastewater pretreatment operation gained cost-effective flexibility and ease of use following installation of the dataTaker DT80 intelligent data logger, which gathered and stored readings from all the different types of water quality sensors. Monitoring, control and data transmission were all handled from the single system. The dataTaker's SCADA interface enabled continual monitoring of all the data in real-time, while the included dEX software made configuration simple and was easy to learn and program.

For more information on the dataTaker DT80 Intelligent Universal Data Logger, other versatile datalogging solutions from dataTaker, or to find the ideal solution for your application-specific needs, contact a CAS Data Logger Applications Specialist at (800) 956-4437 or visit the website at www.DataLoggerInc.com.

Contact Information:
CAS DataLoggers, Inc.
12628 Chillicothe Road
Chesterland, Ohio 44026
(440) 729-2570
(800) 956-4437
sales@dataloggerinc.com
www.dataloggerinc.com
Print | 
Email |  Comment   Share  
Contacts: View detailed contact information.


 

Post a comment about this story

Name:
E-mail:
(your e-mail address will not be posted)
Comment title:
Comment:
To submit comment, enter the security code shown below and press 'Post Comment'.
 



 See related product stories
More .....
 See more product news in:
Test and Measuring Instruments
 More New Product News from this company:
Oven Datalogger is designed for surface coating applications.
Wireless Temperature Dataloggers monitor HVAC performance.
Portable UHF RFID Readers track product temperature.
Output Module for Automotive Applications.
UHF RFID Temp Tags help maintain cold chain.
More ....
| Featured Manufacturing Jobs
 Other News from this company:
AIDS Research Lab Receives Lifetime Accsense Temperature Monitoring
Haitian Hospital Monitors Vaccine Temperatures Over WiFi
CAS DataLoggers to Attend USGS Water Data Conference
CAS DataLoggers Visits Jager and Delphin HQ in Germany
MadgeTech Releases New Data Logger Software Version 4.2
More ....
 Tools for you
Watch Company 
View Company Profile
Company web site
More news from this company
E-mail this story to a friend
Save Story
Search for suppliers of
Data Logging Recorders
Data Collection Systems
Data Loggers & Data Logging Equipment
Join the forum discussion at:
Tools of the Trade
Wired In


Home  |  My ThomasNet News®  |  Industry Market Trends®  |  Submit Release  |  Advertise  |  Contact News  |  About Us
Brought to you by Thomasnet.com        Browse ThomasNet Directory

Copyright © 2014 Thomas Publishing Company. All Rights Reserved.
Terms of Use - Privacy Policy



Error close

Please enter a valid email address