MILWAUKEE, WI -- Danfoss VLT Drives is exhibiting a NEMA 4X-enclosed version of its popular VLT® AQUA Drive at WEFTEC 2011. Engineered with specially designed software for water and wastewater applications, the VLT AQUA Drive is a variable frequency drive that provides seamless installation, commissioning, operation and system maintenance, along with improved energy efficiency, in the water and wastewater industry. WEFTEC is taking place at the Los Angeles Convention Center in Los Angeles, CA, from October 17 - 19, 2011. Danfoss VLT Drives will be exhibiting in South Hall, booth 2230.

Rated NEMA 4X, the VLT AQUA Drive is designed for outdoor installation without the need for an additional enclosure, and delivers reliable operation in temperatures ranging from -10 degrees C to 55 degrees C. These variable frequency drives can be installed with an optional weather shield to protect the heatsink from debris filling up the cooling channel, and to reduce the effect of direct sun. The VLT AQUA Drive also provides 200 mA of 24V to power pressure transmitters to reduce the need for panels and auxiliary power connections. Available options include a fused disconnect, communication cards, and weather-tight USB plug, all of which simplify installation and start-up.

"A new de-ragging feature enables the VLT AQUA Drive to be programmed to rotate backwards to dislodge debris from the impeller, to help keep the pump operating normally. This function can be programmed to run a specific number of cycles for a specified period of time to dislodge the debris," says Jeff Bergman, Danfoss National Product Manager, Water.

The VLT AQUA Drive family significantly improves system efficiency in applications such as water supply, treatment, distribution, pressure and level control, irrigation, and wastewater applications such as pumps and blowers where speed, pressure and/or level control are critical. Its modular design offers the highest flexibility in option selection with fast delivery of a fully factory tested, customized drive with a number of additional plug-and-play options available for simplified upgrades as application needs evolve.

The VLT AQUA Drive offers 98% operating efficiency along with automatic sleep mode functionality, Automatic Energy Optimization and flow compensation to provide considerable energy savings to the user. It is available in NEMA 1, NEMA 12 or NEMA 4X enclosure solutions, and features a compact design with built-in features for easy integration into even the tightest installation spaces. The drive includes a number of pump-specific features to reduce operational costs and protect the pumping system.

Intelligent auto tuning allows the drive to monitor and learn from system reactions to drive corrections and adapt quickly to achieve precise and stable operation. Empty Pipe Fill mode enables controlled filling of pipes to prevent water hammering, bursting pipes and blown sprinkler heads from excessive pressure surges. End-of-curve detection can trigger an alarm or shut down the pump in the event of a break in the line.

The drive will detect when the pump is running dry and will shut it down to prevent damage, while a sleep mode keeps pump wear and power consumption to a minimum. Flow compensation automatically reduces pressure setpoints as appropriate to save energy, and an initial ramp feature allows the pump to quickly accelerate to the minimum frequency while eliminating excessive wear and damage. Up to 20 preventive maintenance events can be scheduled based on the integrated Real-Time Clock. Patented sensorless pressure or flow control enables pump manufacturers to control these variables without the use of sensors. Additionally, a unique "payback" indicator continuously exhibits the amount of time remaining before the investment in these drives pays for itself.

Danfoss VLT Drives
8800 W. Bradley Road
Milwaukee, WI 53224
(800) 621-8806
Fax: (414) 355-6117
www.danfossdrives.com
salesinformation@danfoss.com

Print | 
Email |  Comment   Share  
Contacts: View detailed contact information.


 

Post a comment about this story

Name:
E-mail:
(your e-mail address will not be posted)
Comment title:
Comment:
To submit comment, enter the security code shown below and press 'Post Comment'.
 



 See related product stories
More .....
Don’t hunt for stories like this.
Let Controls & Controllers
Product News Come to You!
Get a Free Subscription
to Product News Alerts.
Start Your Free
Subscription to
Industry Market Trends.
 See more product news in:
Controls and Controllers
 More New Product News from this company:
Vertical Panel Assemblies suit space-restricted applications.
Variable-Speed Drive serves HVAC fan/pump applications.
Compact Motor Soft Starter adapts to application needs.
Temperature Sensor monitors NOx in exhaust gas recirculation systems.
Communications Card fosters PROFINET connectivity.
More ....
 Other News from this company:
Danfoss is Re-approved as Authorized Provider of IACET CEUs
Quality Saves Customer Maintenance Costs
Niels B. Christiansen Becomes President and Chief Executive Officer at Danfoss
Danfoss Announces Major Expansion in Illinois
More ....
 Tools for you
Watch Company 
View Company Profile
Company web site
More news from this company
E-Mail Story
Save Story
Search for suppliers of
Variable Frequency Drives (VFD)
Join the forum discussion at:
Tools of the Trade


Home  |  My ThomasNet News®  |  Industry Market Trends  |  Submit Release  |  Advertise  |  Contact News  |  About Us
Brought to you by Thomasnet.com        Browse ThomasNet Directory

Copyright © 2012 Thomas Publishing Company
Terms of Use - Privacy Policy



Error close

Please enter a valid email address