Quantcast
 
Search for: Search what?
Oct 13, 2008  
 Newsletters
Subscribe Free to Product News Alerts
  
Receive customized, daily news on the products you want.
Subscribe   View Sample
 Categories
Industrial Market Trends
OnSite WebReviews
Latest New Product News
Adhesives and Sealants
Agricultural and Farming Products
Architectural and Civil Engineering Products
Automatic ID
Chemical Processing and Waste Management
Cleaning Products and Equipment
Communication Systems and Equipment
Computer Hardware and Peripherals
Construction Equipment and Supplies
Controls and Controllers
Display and Presentation Equipment
Electrical Equipment and Systems
Electronic Components and Devices
Explosives, Armaments and Weaponry
Fasteners and Hardware
Fluid and Gas Flow Equipment
Food Processing and Preparation
Health, Medical and Dental Supplies and Equipment
HVAC
Labels, Tags, Signage and Equipment
Laboratory and Research Supplies and Equipment
Lubricants
Machinery and Machining Tools
Material Handling and Storage
Materials and Material Processing
Mechanical Components and Assemblies
Mechanical Power Transmission
Mining, Oil Drilling & Refining
Mounting and Attaching Products
Non-Industrial Products
Optics and Photonics
Packaging Products & Equipment
Paints and Coatings
Plant Furnishings and Accessories
Portable Tools
Printing and Duplicating Equipment
Retail and Sales Equipment
Robotics
Safety and Security Equipment
Sensors, Monitors and Transducers
Services
Software
Test and Measuring Instruments
Textile Industry Products
Thermal and Heating Equipment
Timers and Clocks
Transportation Industry Products
Vision Systems
Waste Handling Equipment
Welding Equipment and Supplies
Association News
Browse Categories
Browse Companies
 Press Releases
Products in the News
Company News
Mergers & Acquisitions
People in the News
Literature & Websites
 Resources
News Delivery Options
Mobile Edition
PR Resources
Licensing
Advertising
How to Write an effective Press Release
Trade Associations
Small Business Support
MEP


Advertisement

Story Tools
Tools for Registered Users
   Go Back | Send Story by email E-mail |  Print  
   Save Story |  Watch Company  
Related categories:   Electronic Components and Devices  |  Test and Measuring Instruments

directory searchSearch for suppliers of:
Signal Conditioners
RF Wireless Data Acquisition Modules
View Company Profile at ThomasNet.com
company web site Company web site
more company news View more news from this company

Advertisement

Archive Press Release
(Products mentioned in this Archive Press Release may or may not be available from the manufacturer.)


Dataforth Corp.

Release date: November 7, 2006

Dataforth Adds Frequency Input Modules to 8B Family of Isolated Analog Signal Conditioners

Dataforth Corporation of Tucson, Arizona, has just introduced the latest addition to its family of SensorLex(TM) 8B isolated analog signal conditioners: the 8B45 series of frequency input modules. These modules accept a zero-crossing or TTL level sensor output signal, then isolate, convert, and filter the signal, providing a high-level analog voltage output. Available models provide measurement of a wide range of frequency signals, up to 100kHz; signal amplitudes range from 100mVp-p to 350Vp-p.

A 5V constant voltage excitation source is provided for use with magnetic pickup sensors, contact closure sensors, or other sensors that require a stimulus.

Specific applications for the new modules include the following:

o Any process, industrial or other, that requires precise measurement of frequency signals
o Situations where space is at a premium; 8B45 modules provide signal conditioning in the smallest package available on the market
o Monitoring and control of rotating machinery or equipment
o Health of machine monitoring
o Installations requiring isolation for noise immunity or to break ground loops

Eight input ranges from 500Hz to 100kHz are offered, allowing the modules to fit in virtually any process control application. Other ranges also are available upon request. The modules are encapsulated and sealed and do not require user adjustments over time to maintain calibration.

Both the zero-crossing and TTL input signal paths have built-in hysteresis to prevent spurious noise from corrupting the output signal.

To ensure protection of expensive data acquisition equipment, the 8B45 module signal outputs are protected against accidental connection of voltages up to 240Vrms. All models are designed for operation in Class I, Division 2 hazardous locations and are compliant with European EMC directives.

Additional 8B45 key features, also common to Dataforth's entire 8B family, include: o 1500Vrms Isolation
o ANSI/IEEE C37.90.1 Transient Protection
o ±0.05% Accuracy
o High Common-mode Rejection
o Low Drift with Ambient Temperature
o -40 to +85°C Operating Temperature Range
o 5V Power
o CSA and FM Certifications Pending
o CE Compliant
o Mix and Match Module Types on Backpanel

Developed in response to customer requests worldwide for smaller, lower cost isolated signal conditioners, the SensorLex(TM) 8B family ensures fully functional Instrument Class® performance in a package only one-fifth the size of competing modular products. Since its introduction, the 8B line has grown to include 17 family groups with a total of 102 modules that interface to a wide variety of analog signals such as volt, millivolt, current, temperature (thermocouple and RTD), position, frequency, and strain measuring devices.

Measuring only 1.11" x 1.65" x 0.4" (28.1mm x 41.9mm x 10.2mm), the 8B signal conditioner is 80% smaller than similar products, making it ideal for embedded or portable applications such as mobile test stands, COTS military and defense applications, miniaturized security and surveillance systems, and embedded process controls for semiconductor manufacturing equipment. With the SensorLex 8B, it is now possible to incorporate high-performance modular I/O on a per-channel basis for any embedded monitoring or measurement and control system; because the 8B provides an Instrument Class analog output, interfacing to almost any PC/104, compact PCI, VMEbus, PXI, or proprietary data acquisition system board is very easy.

Housed in a solid, potted thermoplastic plug-in-the-panel package with flammability rating of UL-94 V-0, the 8B family of isolated signal conditioners is specifically designed to protect user equipment, while reducing electrical noise and enabling convenient system expansion and repair. All 8B modules offer dimensional stability over temperature, chemical resistance, and excellent stability over time; they do not require recalibration.

Operation and storage temperature for the 8B models is -40 to +85 C; relative humidity range is zero to 95% noncondensing. All models meet the requirements of EN61000-6-4 (radiated/conducted emissions) and EN61000-6-2 (ESD/RF/EFT immunity). For operation in hazardous environments, North American Class I, Division 2, and European Group II, Category 3, approvals are pending.

Design-in accessories for the 8B line include a selection of backpanels (2-, 4-, 8-, and 16-channel) that provide screw-terminal inputs and outputs as well as a DB25 header connector that connects 8B outputs to a user's data acquisition system. The DB25 header can be matched with 1-, 2-, or 7-meter cables, available as accessories, to connect sensors and transducers to an external 25 screw-terminal interface board.

Coming months will see the introduction of true RMS input modules and 2-wire transmitter interface modules. Custom signal conditioning models are available to meet unique signal conditioning needs. Prices for 8B modules start at $89.

For additional information, call 800-444-7644 toll-free, e-mail sales@dataforth.com, or visit our website at www.dataforth.com. A Worldwide Network of Sales and Distributor Channels
US Toll Free: 800.444.7644
Phone: 520.741.1404
Fax: 520.917.2254
E-mail: sales@dataforth.com

Dataforth products are manufactured in the USA at:
Dataforth Corporation
3331 E Hemisphere Loop
Tucson, Arizona (AZ) 85706-5011
USA

Company Information:
Name: Dataforth Corp.
Address: 3331 E. Hemisphere Loop
City: Tucson
State: AZ
ZIP: 85706
Country: USA
Phone: 800-843-5538
FAX: 520-741-0762
http://www.dataforth.com

More New Product News from this company:
Aug 4, 2008 - Software provides supervisory control and DAQ solution.
Jul 15, 2008 - Transmitter Interface Modules provide isolation.
May 16, 2008 - Industrial DAQ System offers dual Ethernet.
Jun 15, 2007 - Signal Conditioner measures 2.28 x 2.26 x 0.6 in.
Nov 8, 2005 - Data Logger offers stand-alone or PC-tethered operation.
Jun 28, 2005 - Data Acquisition System supports Modbus protocols.
Jun 17, 2005 - Analog Voltage I/O Modules provide 1 kHz bandwidth.
Feb 18, 2005 - Signal Conditioners suit embedded or portable applications.
May 12, 2004 - Data Acquisition System is CE compliant.
Mar 11, 2003 - Data Acquisition System accepts digital or analog modules.

Other News from this company:
Apr 01, 2006 - Dataforth Adds Accelerometer Input Module to SCM5B Family of Isolated Analog Signal Conditioners

Advertisement


More related stories:
Oct 1, 2008 - Mesh Networking Protocol suits battery-powered networks.
Sep 30, 2008 - Signal Conditioning Module works with inductive transducers.
Sep 16, 2008 - Analog Transmitter provides 4-20 mA or 0-10 Vdc output.
Aug 25, 2008 - Signal Conditioning System is modular and programmable.
Aug 13, 2008 - Signal Generator allows multiple units to be stacked.
Jul 30, 2008 - RF Module offers direct analog input.
Jul 9, 2008 - Analog Front End targets portable ultrasound systems.
Jul 7, 2008 - IEPE Signal Conditioning Board features 4 channels.
Jun 30, 2008 - Wireless Development Kits meet Bluetooth and 915 MHz needs.
Jun 26, 2008 - Signal Conditioner features 3-way signal isolation.
Jun 25, 2008 - Encapsulated Signal Conditioner suits rugged environments.
Jun 24, 2008 - Signal Conditioners aid in automotive component testing.
Jun 16, 2008 - Signal Conditioning Board eliminates ground loops.
Jun 2, 2008 - Signal Conditioners are DIN rail mount configurable.
May 22, 2008 - Signal Conditioner is designed for process monitoring.
May 12, 2008 - Timing, Signal Conditioning Products address PCIeG2 demand.
Apr 22, 2008 - DC Sensor Signal Conditioner features selectable gain.
Mar 13, 2008 - Signal Conditioners feature self-calibrating circuitry.
Mar 4, 2008 - Load Cell Amplifier is available in lead-free version.
Feb 8, 2008 - Analog IC includes adjustable resistor technology.



Story Tools
Tools for Registered Users
   Go Back |  Send Story by email E-Mail  |  Print  |  Post   
   Save Story |  Watch_Company  


Get Copyright Clearance Want to use this article? Click here for options!
Copyright 2006 Thomas Publishing Company

 

Brought to you by Thomasnet.com        Browse ThomasNet Directory

Copyright © 2008 Thomas Publishing Company
Terms of Use - Privacy Policy