CAS Data Loggers
Latest New Product News
Single-Phase Energy Equipment Logger constantly samples data.CAS Data Loggers
Chesterland, OH 44026
Feb 28, 2013
Recording AC voltage and current, Electrocorder Single-Phase Energy Data Logger Kit includes datalogger, analysis software, voltage leads, and USB lead. Kit monitors one voltage channel and one current channel, recording energy consumption up to 300 V and 16 A. When recording, average voltage and current, along with max/min cycle values, are stored over chosen period of 1 sec to 60 min. Every cycle is sampled multiple times for up to 300 days of continuous recording.
 Datalogger Software meets monitoring and alarming requirements.CAS Data Loggers
Chesterland, OH 44026
Feb 20, 2013
PC-based configuration and analysis solution, SiteView, ties together features of Accsense VersaLog monitoring and alarming devices. With its graphic interface, data visualization and presentation solution facilitates setup for recorders and enables logging across sampling time range of 20 msec to 12 hr. To accelerate downloads, SiteView supports communication speeds up to 115,200 bps as well as multiple file loading. Users can also view alarm triggers, zoom in on data, and annotate.
 Ethernet Temperature Data Loggers feature DHCP compliance.CAS Data Loggers
Chesterland, OH 44026
Feb 15, 2013
Meeting regulatory specifications, including RFC 2131 standard, Accsense A2-05 serves critical temperature monitoring and alarming applications in healthcare, research, and industry. Each pod measures and records temperature data by connecting to medical storage units with inputs for 2 RTDs and Type T thermocouple. Along with DHCP (Dynamic Host Configuration Protocol) compliance, features include -199 to +400°C measurement range, PoE support, and instant alarming functionality.
 CDMA RTU offers remote monitoring where GSM is not available.CAS Data Loggers
Chesterland, OH 44026
Feb 14, 2013
With ADU-500L CDMA Data Logger Telemetry System, several transmitters can send information simultaneously over single communication channel, letting several users share band of frequencies. Battery-powered unit incorporates 2 analog inputs measuring at 12-bit resolution, 3 digital inputs, and I2C interface supporting external digital sensors. SMS messages are used for wireless logged data transfer, event-driven alarm messages, and periodic status messages for verifying unit availability.
 Multichannel Voltage/Current Datalogger has real-time alarming.CAS Data Loggers
Chesterland, OH 44026
Feb 05, 2013
For real-time monitoring alarming applications, stand-alone Accsense VersaLog provides 7 range-programmable voltage and current external input channels and one channel for recording ambient temperature. Sampling is user-selectable from 20 msec to 12 hr, and 4 MB Flash memory stores up to 2 million measurements. Utilize 16-bit ADC converter, datalogger comes with Windows® analysis software, splash-resistant aluminum enclosure, and support for USB, Modem, and Ethernet connections.
 Wi-Fi Data Loggers track temperatures from -4 to +140°F.CAS Data Loggers
Chesterland, OH 44026
Jan 22, 2013
With internal sensor, EL-Wifi-T continually monitors ambient temperature and transmits values via Wi-Fi network to PC for viewing/export. LCD shows Max and Min readings along with Low Battery and Wi-Fi connection status, and any alarm breach is instantly registered on device and PC screen. If sensor loses network connectivity, this IP55-rated, USB-enabled logger with internal lithium polymer battery continues taking readings until able to communicate with PC application.
 USB Temperature Data Loggers target cold chain applications.CAS Data Loggers
Chesterland, OH 44026
Jan 17, 2013
Intended for stand-alone temperature monitoring, I-Plug-Plus Data Loggers help protect perishable products in trucks and warehouses. Single-use units monitor temperature from -30 to +70°C with 0.5°C accuracy. Loggers provide 5,000 sample memory, 1-year battery life, and user-selectable sampling rate from 1 sec to every 24 hr. With LED status and alarms lights, users can see when product temperatures are OK, Below, or Over. Built-in USB interface enables connection to PC for downloading data.
 Thermocouple Logger features built-in alarming and graphing.CAS Data Loggers
Chesterland, OH 44026
Jan 11, 2013
Suited for spot checking, handheld EL-ENVIROPAD-TC takes and records temperature readings via supplied K-type probe over -292 to +2,372°F range. Data Logging mode lets users set unit to take temperature readings at pre-determined intervals for any desired length of time. As many as 65,536 readings can be saved to integrated memory, along with date/time stamp, and downloaded to PC via micro USB connection. Mini-thermocouple connection is compatible with J/K/N/T-type probes.
 Thermocouple Data Loggers offer real-time continual monitoring.CAS Data Loggers
Chesterland, OH 44026
Jan 10, 2013
Featuring 8 channels and 16-bit ADC, Accsense VersaLog TC Temperature Data Loggers are suitable for life science, laboratory, and medical monitoring applications. Battery-powered, stand-alone units include 7 internal input channels that accommodate all types of external thermocouple probes. Supporting USB, serial, and Ethernet connections for local and remote access, devices provide alarm and excitation output that warn when critical parameters go out of specification.
 Stand-Alone Dataloggers offer alarm outputs, 4 MB Flash memory.CAS Data Loggers
Chesterland, OH 44026
Jan 08, 2013
Used for real-time temperature monitoring and alarming, Accsense VersaLog includes temperature/humidity and current/voltage models; thermocouple and ambient temperature versions are also available. Features include analysis and plotting software, 7–8 channels for monitoring, 16-bit ADC, and support for USB, serial, and Ethernet connections. Suited for unattended data recording and storage, these portable, battery-powered dataloggers offer sampling interval range from 20 msec to 12 hr.
 Dual-Channel Logger records DC voltage and current.CAS Data Loggers
Chesterland, OH 44026
Dec 17, 2012
Provided in kit with DC current probe, 3 fused voltage leads, USB lead, 12 Vdc PSU, and software, Two Channel DC Voltage and Current Data Logger monitors 1 or 2 DC voltage channels from 1–300 V and one DC current channel (±10 or ±100 A). IP65-rated unit records avg, max, and min values, and accommodates diverse battery testing applications. User-selectable averaging period from 1 sec to 60 min is accurate to less than 1% of range, and memory capacity is 32,000 true RMS values per channel.
 Power Quality Analyzer records and displays power issues.CAS Data Loggers
Chesterland, OH 44026
Dec 05, 2012
Suitable for troubleshooting single- or 3-phase balanced load networks, PowerPad Jr. 8230 measures and records power system quality and performs energy metering. Data logger measures up to 660 Vrms or Vdc as well as 6,500 Aac or 1,400 Adc, recording and displaying 17 power quality parameters. Users can also determine harmonic problems and display THD. Able to store up to 1 MB of data and up to 8 screen captures, analyzer includes DataView software for calculation and analysis.
 Power Quality Analyzer provides in-depth troubleshooting.CAS Data Loggers
Chesterland, OH 44026
Nov 29, 2012
Used to find and analyze specific power issues such as disruptive power spikes in plant power distribution panels and individual machines, PowerPad Model 8335 comes with DataView software for calculation and analysis and lets users measure and carry out diagnostic and power quality work on 1-, 2-, or 3-phase low-voltage networks. Portable power logger also allows verification of power distribution circuits and pad mount transformer monitoring.
 Modbus Wireless Gateway integrates GPRS technology.CAS Data Loggers
Chesterland, OH 44026
Nov 06, 2012
With AirGate Modbus Wireless Gateway, users can monitor critical data from anywhere in building or remote offices, helping to avoid potentially disastrous product loss. Users can select from 4 operation modes: Modbus Master, multiplexer, USBRS485 converter, and simple wireless RS485 extension. Featuring up to 16 channels and max transmission power of 100 mW, gateway can achieve RF data rate up to 250 Kbps and serial port baud rate of 1,200 to 115.2 Kbps.
 Ethernet Data Loggers measure temperature and humidity.CAS Data Loggers
Chesterland, OH 44026
Nov 05, 2012
Incorporating Ethernet/LAN interface with built-in 10BaseT connection, TR-7W Series can collect recorded data, monitor current conditions, and send warning e-mails when refrigerator/freezer temperatures go out of specification. Two-channel temperature logger has measurement range of -40 to 110°C, while temperature/humidity logger measures temperature from 0–50°C, humidity from 10–95% RH, and offers optional wireless interface. Both include 16,000 point memory for extended logging.
 Power/Energy Datalogger integrates 67 x 55 mm backlit LCD.CAS Data Loggers
Chesterland, OH 44026
Oct 24, 2012
Designed for load center panel installation, PEL 103 single-phase, 2-phase (split-phase), and 3-phase (Y, Δ) power/energy datalogger records, captures, and analyzes data every second. Unit can measure and record 3 voltage inputs and current inputs, Watts, VARS, VA, and energy as well as calculate power factor, displacement power factor, crest factor, frequency, and THD. Measurement and calculation is also possible for harmonics up to 50th order for 50/60 Hz and 7th order for 400 Hz.
 Datalogger enables power factoring for energy conservation.CAS Data Loggers
Chesterland, OH 44026
Oct 24, 2012
Designed for load center panel installation, PEL 102 single-phase, 2-phase (split-phase), and 3-phase (Y, Δ) power/energy datalogger measures, stores, and analyzes data every second. Unit can measure 3 voltage inputs and current inputs, Watts, VARS, VA, and energy as well as calculate power factor, displacement power factor, crest factor, frequency, and THD. Meter also enables measurement, calculation, and display of harmonics up to 50th order for 50/60 Hz and 7th order for 400 Hz.
 Temperature Recorder features Wi-Fi connectivity.CAS Data Loggers
Chesterland, OH 44026
Oct 10, 2012
Suited for diverse environments, EasyLog WiFi Temperature Probe Data Logger measures temperature of probe's surroundings within -40 to +257°F range. Current temperature reading is shown on integrated display, and all data can be transmitted via Wi-Fi network to PC for viewing. If network connectivity is lost, sensor keeps recording until able to communicate with PC application (120 days max at 10 sec sample interval). When installed on PC, software enables setup and data logging/review.
 Digital I/O Card extends DAQ system capabilities.CAS Data Loggers
Chesterland, OH 44026
Oct 05, 2012
Designed for ADwin-Pro-II Modular Real-Time Data Acquisition and Control System, DIO-32-TiCo provides applications with 32 TTL I/Os, built-in edge detection or edge output with time stamp, and 256 MB external memory. Module also features local TiCo processor with 100 MHz clock to detect events within 100 ns at 5 ns accuracy. With local processor, user can download part of application to run on card without requiring interaction and management from ADwin system's main processor.
 Wireless Data Logger records temp/RH/CO2 in real-time.CAS Data Loggers
Chesterland, OH 44026
Oct 02, 2012
Featuring professional-grade NDIR sensor technology, Model RTR-756 enables real-time monitoring of indoor air quality and automatic data collection from remote locations. Self-contained unit simultaneously monitors and records CO2 concentration, temperature, and humidity, making it suitable for use in schools and office buildings, as well as testing ventilation and air conditioning controls. Battery-operated logger self-corrects for altitude, and is backed up so users do not need to plug it in.
Click below for more Product News from CAS Data Loggers
Company News Home
Next News Stories
|
|