Palmer Wahl
Latest New Product News
 IR Thermometer offers long range operation.Palmer Wahl
Asheville, NC 28804
Jan 21, 2010
Designed for use in electrical power generation and transmission industry, Model HSA300 features 300:1 optics, which provide 2 in. measurement spot at 50 ft. Peak temperature is displayed on large main display, while current temperature is displayed on smaller secondary display. Able to measure from 300 ft away, thermometer includes telescopic sight that allows precise positioning of measurement spot while maintaining safe distance from target.
 Black Body Calibrator helps maintain NIST traceability.Palmer Wahl
Asheville, NC 28804
Sep 22, 2009
Wahl® Heat Spy Portable Calibration Black Body is used for single-point calibration verification and checking of IR instruments such as thermal imaging cameras and point IR thermometers. Ambient temperature black body features accuracy of ±.3°F. Housed in watertight IP67 carrying case, it includes NIST Traceable Certificate of Calibration and replaceable battery with 3 yr operational life.
RTD Thermometers offer ±0.3°F accuracy over 1 yr period.Palmer Wahl
Asheville, NC 28804
Feb 16, 2009
Available in standard and custom probe configurations, DST500 Temperature Indicator and DSX500 Transmitter Thermometers feature 1 in. high LCD display, readable from 30 ft away. Model DST500 includes field replaceable battery with 2-yr operational life, while DSX500 is loop-powered from integral, 4-20 mA transmitter. Factory configurable to user's specification, thermometers offer temperature range of -328 to 1,472°F and come with NIST Traceable Certificate of Calibration.
RTD Thermometer offers alternative to mercury-in-glass.Palmer Wahl
Asheville, NC 28804
Sep 30, 2008
Utilizing thin-film platinum RTD sensor along with self-testing circuitry, Wahl® DST600 offers measuring range of -50 to 500°F with total system accuracy of ±0.3°F over 1-yr period. Unit meets FDA Proposed Rule change to 21 CFR Part 113, which allows replacement of mercury-in-glass thermometers with other technologies. Available with MIG standard tapered bulb chambers, or various probe configurations, device is suited for food canning retorts, dairy, and pharmaceutical applications.
 RTD Thermometer System meets FDA standards.Palmer Wahl
Ashville, NC 28804
Aug 07, 2008
Wahl® DST600 uses thin-film platinum RTD sensor along with self-testing circuitry which continuously verifies electronics to ensure reading accuracy, rated ±0.3°F over -50 to +500°F temperature range. Offered as drop-in mercury-in-glass (MIG) thermometer replacement, solution is available with MIG standard tapered bulb chambers or variety of probe configurations. It meets FDA Proposed Rule change to 21 CFR Part 113 as well as current USDA 9CFR318.300 and 9CFR381.300 standards.
 Thermal Imaging Camera locates hot spots.Palmer Wahl
Ashville, NC 28804
Apr 25, 2008
Hot Spot Finder HSI1200 provides real-time thermal image for fault detection combined with center spot, non-contact temperature measurement function. Designed for self-contained use, handheld unit features trigger-activated laser pointer and 20° x 20° Field of View. Its 16 x 16 pixel array can display thermal images on backlit 3.5 in. color LCD, and report writing software supports insertion of multiple images with data. Temperature is measured for all 256 pixels displayed on camera.
 Thermal Imaging Camera has 9.1° x 6.8° field of view optics.Palmer Wahl
Ashville, NC 28804
Nov 20, 2007
Long Distance model HSI3003 features 160 x 120 pixel, uncooled microbolometer array capable of displaying high-resolution, real-time images on 3.5 in. color LCD with LED backlight. With temperature range of 32-482°F, it includes trigger activated, Class II laser that identifies problem hot spot shown on marked center of display. Compact, handheld unit is fully radiometric and has 2 measurement cursors that provide readings at each cursor location.
 Thermal Imager takes high-temperature measurements.Palmer Wahl
Ashville, NC 28804
Oct 25, 2007
With range of 392 to 1,652°F, High Temperature HSI3002 Heat Spy® Thermal Imaging Camera has 20° x 15° field of view and trigger-activated, Class II laser. Integral 160 x 120 pixel, uncooled, microbolometer array displays hi-res, real-time, thermal images on 3.5 in. color LCD with LED backlight. Fully radiometric unit measures temperature of every pixel, and Easy Report software lets user insert multiple images, with data, taken during site survey to produce inspection reports.
 Micro-Ohmmeter also gives real-time temperature readings.Palmer Wahl
Ashville, NC 28804
Aug 17, 2007
With 0.1°C resolution and ±0.5°C accuracy, Wahl RM116 Micro-Ohmmeter performs measurements on inductive and non-inductive resistances with dc current. Interactive display informs operator about measurement type, range, calculation conditions, thresholds status, and values. Designed for harsh conditions in hard Pelicase®-type case with plastic washable keyboard and key-locked measurement plugs, battery-powered low resistance tester has 4 measurement wires and 1,000-measurement memory.
 Calibrators feature IP54 rating and multilingual operation.Palmer Wahl Instrumentation Group
Asheville, NC 28804
Jan 19, 2007
On-site Multifunction Model C50 measures and generates, on 2 isolated channels, voltage, current, frequency, and resistance signals as well as various resistive probes and thermocouples. Dual display simultaneously indicates measurement value, emitted value, gauge, and selected parameter functions. Designed for outdoor use, Pocket Process Calibrator/Meter, Model P32 meets needs of transmitters and process sensors using 4-20 mA or 0-10 V signals and provides 0.015% accuracy.
 Pocket Thermometers withstand harsh process environments.Palmer Wahl
Ashville, NC 28804
Oct 03, 2006
Handheld Models TM602, TM612, and TM630 measure thermocouples, RTDs, and both T/C and RTDs, respectively. They can measure with accuracy of 0.02% of reading and temperature coefficient of 15 ppm/°C, 14 different thermocouple outputs, and 12 RTD types with temperature coefficient of 10 ppm/°C. All include graphical LCD with adjustable contrast and backlight. Data can be recorded either manually on event or automatically with user-programmed frequency.
 Thermal Imaging Camera is suited for building diagnostics.Palmer Wahl Instrumentation Group
Asheville, NC 28804
Aug 14, 2006
Used for monitoring electrical and mechanical systems, Heat Spy® HSI3000 employs 160 x 120, uncooled microbolometer array and trigger-activated Class II laser. Ergonomic, handheld unit also features 3.5 in. color LCD with LED backlight. Dual measurement cursors, movable anywhere in image, provide temperature readings at each cursor location and indicate real-time differential temperature measurement between 2 points anywhere along 14 to 482°F range.
 Pocket Calibrators suit probe and transmitter maintenance.Palmer Wahl Instrumentation Group
Asheville, NC 28804
Aug 14, 2006
Pocket temperature calibrators are designed for maintenance and commissioning of thermocouple, RTD probes, and transmitters. Featuring simulation, synthesizer, steps, and measurement modes, devices can record data manually or automatically. Wahl TC621 and TC622 measure and simulate with 0.02% accuracy of reading, with temperature coefficients of 15 and 10 ppm/°C, respectively. TC621 includes 14 thermocouple outputs, and TC622 includes 12 different RTD types.
 Pocket Calibrators help maintain probes and transmitters.Palmer Wahl
Ashville, NC 28804
Jul 28, 2006
Thermocouple calibrator, Model TC621, can measure and simulate with accuracy of 0.02% of reading, temperature coefficient of 15 ppm/°C, and 14 different thermocouple outputs. Model TC622 also measures and simulates with accuracy of 0.02% of reading, but with temperature coefficient of 10 ppm/°C and 12 RTD types. With measurement mode, users can create database to design curves for sensors, after calibration, in relationship with corrections shown on calibration report.
 Portable IR Thermometer logs measurements to memory.Palmer Wahl Instrumentation Group
Asheville, NC 28804
Jul 11, 2006
Along with USB data output, hand-held Heat Spy® DHS215XEL features type K thermocouple ANSI mini-jack input and 4-digit backlit dual LCD display for measuring and displaying non-contact and contact surface temperatures in ºF or ºC simultaneously. Product has adjustable emissivity setting and -58 to +1,832ºF temperature range. To measure smaller targets from greater distances, unit incorporates selectable On/Off laser sighting system and distance-to-target ratio of 50:1.
 Camera System thermally screens individuals for Bird Flu.Palmer Wahl Instrumentation Group
Asheville, NC 28804
Apr 20, 2006
Designed for mass screening of public areas for individuals with elevated body temperatures, Wahl Fever Alert Imaging System produces real-time thermal picture of facial skin surface temperature as each person passes by camera. Included software triggers both visual and audible alarm if temperature reading is above user-defined threshold. System can resolve surface temperature differences of ±0.5ºC.
 Sensor/Transmitter Calibrator provides 0.015% accuracy.Palmer Wahl Instrumentation Group
Asheville, NC 28804
Jan 23, 2006
Pocket Process Calibrator/Meter Model P32 facilitates maintenance operations and installation of sensors and transmitters using process signals such as 4-20 mA or 0-10 V. Unit offers adjustable resolution from 1/10 to 1/1,000 of value measured. Calibrator can generate simple or cycle ramps with adjustable high and low levels, rising and falling times, and stabilization time. It includes scaling, statistical calculation, hold, and filter functions.
 Indicator provides permanent record of overheating.Palmer Wahl Instrumentation Group
Asheville, NC 28804
Nov 29, 2005
Applied to clean, dry surface on circuit breakers, motors, and electrical equipment, self-adhesive Wahl Breaker WB140 visually indicates possible component failure or overheat. It provides 24/7 continuous monitoring, with no interruption due to power failure or battery exhaustion. Traceable to NIST standards, temperature-recording label has silver gray indicator that turns permanently and irreversible black in less than one sec with ±1% accuracy.
 Thermal Imaging Camera helps with predictive maintenance.Palmer Wahl Instrumentation Group
Asheville, NC 28804
Jun 01, 2005 Available in portable and fixed models, Heat Spy® Imager locates hot spots while indicating temperature and delta T. Images with temperature points and differentials can be saved and reviewed later, and each picture is date/time stamped and can be labeled accordingly. Operating with virtual instrumentation software and programmable operator controls, fixed version can monitor process and feedback up to 256 temperature points simultaneously.
 Dial Thermometers suit HVAC and process applications.Instrumentation Group
Asheville, NC 28804 1228
Sep 26, 2002 All Proâ„¢ Bimetal Thermometers have all stainless steel construction and come in 2 in. back-connected dial, and 3 and 5 in. dial sizes with back, bottom, and all angle case styles. Connections are ¼ in. NPT on 2 in. dials and ½ in. NPT on 3 and 5 in. dials. Units provide 1% span accuracy and spun-over, non-removable sealed bezel ring. F and C scales are color coded for easy reading.
Click below for more Product News from Palmer Wahl
Company News Home
Next News Stories
|
|