Company News

CAS DataLoggers

12628 Chillicothe Rd., Chesterland, OH, 44026, US

  • 440-729-2570
  • 800-956-4437
Share Like Tweet Add Email

Latest New Product News from
CAS DataLoggers

Test & Measuring Instruments

Paperless Chart Recorders offer real-time monitoring.

December 18, 2014

Designed for measuring voltage, current, thermocouples, or RTDs from remote locations, Brainchild PR Series is suitable for laboratories, hospitals, and factories. Model PR-10 features 4.3 in. touchscreen display and 6 channels, while Model PR-20 has 5.6 in. touchscreen and 6 channels. Equipped with 12.1 in. touchscreen, Model PR-30 provides up to 48 input channels. Recorders offer scan rate within 100 msec for all analog channels and can store data on internal Flash memory. Read More

Computer Hardware & Peripherals

CPU Module features ARM-based technology for real-time speed.

December 4, 2014

Available for ADwin-PRO II data acquisition and control systems, ADwin Pro-CPU-T12 Processor Module offers high-speed real-time computing power. Module executes ADbasic instructions and accesses inputs, outputs, and interfaces of other modules. In addition to XILINX ZYNQ™ with Dual-Core ARM Cortex-A9, unit features 64-bit FPU, 1 GHz processor clock, 1 GB main memory for code and data, trigger input, 2 digital I/Os, and 1,000 Mbit Ethernet interface for communication to PC. Read More

Test & Measuring Instruments

Graphing Voltage Data Logger records up to 16 channels.

November 28, 2014

With recording interval as short as 2 ms and minimum voltage resolution of 10 µV, Model MCR-4V offers way to measure and record voltage data for control devices and measurement instruments in electrical circuits. Up to 4 units can be coupled together for simultaneous measurement and recording of up to 16 channels. Users can download data via USB connection or optional SD Flash Memory card. Utilizing trend graphing feature, users can check data in real-time while in field. Read More

Test & Measuring Instruments, Sensors, Monitors & Transducers, Controls & Controllers

Wireless Temperature Datalogger supports medical monitoring.

November 18, 2014

Suitable for medical refrigerator/freezer, WiFi-enabled Accsense A2-05W features inputs for 2 external RTD temperature probes with temperature range of -100 to +100°C and additional input for thermocouple measuring down to -200°C for cryogenic storage units. Datalogger supports 802.11a/b/g/n specifications as well as WEP, WPA, WPA2, 802.11i, and 802.1x Supplicant. Users can login through any Web browser to view real-time reports and graphs of data or configure system from anywhere via Internet. Read More

Test & Measuring Instruments, Sensors, Monitors & Transducers, Controls & Controllers, Green & Clean

Intelligent Dataloggers send HVAC/R data over BACnet.

November 17, 2014

When connected to Modbus gateway, Series 3 dataTaker Intelligent Data Loggers can communicate over BACnet for such HVAC verification applications as energy efficiency and air quality monitoring. Universal analog input channels provide flexibility to monitor temperature, humidity, and current/voltage; store data to memory; and transfer it over Bacnet. These intelligent dataloggers also incorporate serial and Ethernet capabilities. Read More

Test & Measuring Instruments, Green & Clean, Sensors, Monitors & Transducers

Energy Audit Kit records usage and verifies performance.

November 12, 2014

Used for energy auditing/verification, EC-7VAR Three-Phase Power & Energy Datalogger Kit can record energy (kWh) and power (kW) usage and provides everything needed: datalogger, voltage leads, transducers, Rogowski coils, case, software, and USB lead. Users can view onsite power consumption as result of logging. Electrocorder 3-phase power factor dataloggers monitor 1, 2, or 3 current channels (up to 400 A, 1 kA, 2 kA, or 3 kAac) as well as 1, 2, or 3 voltage channels (30–500 Vac). Read More

Test & Measuring Instruments, Sensors, Monitors & Transducers

Configurable Thermocouple Dataloggers communicate over Wi-Fi.

November 7, 2014

Able to send data over Wi-Fi® network, Lascar El-WiFi-TC dataloggers are supplied with K-type thermocouple probe with 0 to +400°C measurement range and ±1.5°C accuracy. Connection support also covers J/K/N/T thermocouple types for -270 to +1300°C measurement range. End-users can view real-time temperature data, which is continually monitored, using FilesThruTheAir™ Cloud storage service or integrated display. Fail-safe recording and logged data retention are standard. Read More

Test & Measuring Instruments

Portable Monitoring System enables mobile measurement.

October 23, 2014

With 14 universal analog and 8 digital inputs, Expert Key 100 M features detachable screw terminals and 4 mm laboratory connectors that enable direct connection of sensors and actuators as well as thermocouples and RTD sensors. PC-based data acquisition solution includes ProfiSignal software and Windows 8.1 tablet PC. Data exchange is possible via access point, external antenna, or USB and Ethernet ports. Outputs enable control procedures to be triggered and alarms for limit violations. Read More

Other Company News from
CAS DataLoggers

November 25, 2013

What Is a Data Logger?