South Bend Controls, Inc.

Isolation Valve mounts directly on manifold.
Fluid & Gas Flow Equipment

Isolation Valve mounts directly on manifold.

Two-way solenoid valve mounts on manifold, is rated up to 35 psi with Cv of 0.05, and is available in 12 and 24 Vdc models, in normally open or normally closed versions. Materials in contact with flow path are limited to PEEK (polyetheretherketone) and EPDM (ethylene propylene) or FKM (highly-fluorinated fluorocarbon). Applications include blood analysis, clinical chemistry, DNA processing,...

Read More »
Inert Valve controls corrosive or high-purity fluids.
Fluid & Gas Flow Equipment

Inert Valve controls corrosive or high-purity fluids.

Solenoid-operated IPV inert proportional diaphragm isolation valve can be used in medical equipment, water purification and clinical chemistry industries. Materials of all surfaces in flow path are inert and impervious to wide range of aggressive fluids. Valve provides infinitely variable flow control, is rated to 60 psi, and has 24 Vdc driver. Poppet and seat are configured to provide bubble...

Read More »
Inert Diaphragm Valve handles aggressive fluids.
Fluid & Gas Flow Equipment

Inert Diaphragm Valve handles aggressive fluids.

Three-way IDV solenoid-operated diaphragm isolation valve works with fluids found in medical equipment, water purification and clinical chemistry industries. Materials of all surfaces in flow path are inert and impervious to many aggressive fluids. Valve is typically used in waste circuits where valve must tolerate high contaminant levels. Valve is rated 35 psi with Cv of 0.22 and is available in...

Read More »
Isolation Valve mounts directly on manifold.
Fluid & Gas Flow Equipment

Isolation Valve mounts directly on manifold.

Two-way solenoid valve mounts on manifold, is rated up to 35 psi with Cv of 0.05, and is available in 12 and 24 Vdc models, in normally open or normally closed versions. Materials in contact with flow path are limited to PEEK (polyetheretherketone) and EPDM (ethylene propylene) or FKM (highly-fluorinated fluorocarbon). Applications include blood analysis, clinical chemistry, DNA processing,...

Read More »
Inert Valve controls corrosive or high-purity fluids.
Fluid & Gas Flow Equipment

Inert Valve controls corrosive or high-purity fluids.

Solenoid-operated IPV inert proportional diaphragm isolation valve can be used in medical equipment, water purification and clinical chemistry industries. Materials of all surfaces in flow path are inert and impervious to wide range of aggressive fluids. Valve provides infinitely variable flow control, is rated to 60 psi, and has 24 Vdc driver. Poppet and seat are configured to provide bubble...

Read More »
Inert Diaphragm Valve handles aggressive fluids.
Fluid & Gas Flow Equipment

Inert Diaphragm Valve handles aggressive fluids.

Three-way IDV solenoid-operated diaphragm isolation valve works with fluids found in medical equipment, water purification and clinical chemistry industries. Materials of all surfaces in flow path are inert and impervious to many aggressive fluids. Valve is typically used in waste circuits where valve must tolerate high contaminant levels. Valve is rated 35 psi with Cv of 0.22 and is available in...

Read More »

All Topics