SKC, Inc.

Personal Impactor collects coarse/fine/ultrafine particles.
Material Processing

Personal Impactor collects coarse/fine/ultrafine particles.

Sioutas Cascade Impactor separates and collects airborne particles in 5 size ranges: greater than 2.5 micron, 1.0-2.5 micron, 0.50-1.0 micron, 0.25-0.50 micron, and less than 0.25 micron. Unit is used with PTFE filters for minimal particle bounce and preservation of unstable compounds and clips to worker's collar or lapel for personal or area sampling. Optimal particle separation at specified...

Read More »
Air Sampling Pump features battery-powered operation.
Fluid & Gas Flow Equipment

Air Sampling Pump features battery-powered operation.

Designed to run at 1 L/min, Grab Air Sample Pump collects air into sample bags to assess exposure from airborne chemical hazards. It operates on 9 V battery, yielding up to 1,000 L volume. Recommended for sample bags with up to 10 L capacity, process is complete when bag is properly filled. Pump suits areas where leaks, spills, or other potentially hazardous events have occurred and concentration...

Read More »
Mold Sample Pump provides constant flows from 10-30 l/min.
Fluid & Gas Flow Equipment

Mold Sample Pump provides constant flows from 10-30 l/min.

Portable QuickTake 30 is suited for use with BioStage Impactors, BioCassette, spore trap cassettes such as VersaTrap or Air-O-Cell, and wall cavity samplers. Large keypad allows user to select preset sample time or customize timer up to 999 min. Front-mounted intake allows fast media setup, while intermittent and continuous run modes expand operation. Rechargeable lithium-ion battery pack...

Read More »
Sample Pump features low-noise design.
Fluid & Gas Flow Equipment

Sample Pump features low-noise design.

Model IAQ-3 provides constant flows from 5-3,250 ml/min for indoor air sampling applications. Manual programming is accomplished via 3-button keypad on pump. PC programmability allows delayed start, timed shutdown, intermittent sampling, and data management. Internal sensor measures flow directly and acts as secondary standard maintaining set flow. Pump is suited for use with sorbent tubes,...

Read More »
Color Change Wipes detect amount of lead on surfaces.
Cleaning Products & Equipment

Color Change Wipes detect amount of lead on surfaces.

Full Disclosure Wipes indicate presence of lead on skin and irregular surfaces such as safety glasses, steering wheels, and shoes. Product alerts worker to presence of lead residue following handwashing or cleaning regimens: user needs only to wipe surface, spray wipe with solutions, and observe color change. Yellow is negative for lead presence, and red is positive. Intensity of red bloom...

Read More »
Foil Grab Bags feature 4-layers to prevent permeation.
Agricultural & Farming Products

Foil Grab Bags feature 4-layers to prevent permeation.

Foil Grab Bags provide light and moisture protection for samples of low molecular weight compounds that are unstable in TedlarÂ-® sample bags. Inner surface is inert, minimizing absorption and adsorption of collected compounds. Evenly sealed seams make bags suitable for mailing or shipping samples to laboratory for analysis. Foil Grab Bags include stainless steel or polypropylene all-in-one...

Read More »
Passive Samplers utilize 2,4-DNPH chemistry.
Laboratory and Research Supplies and Equipment

Passive Samplers utilize 2,4-DNPH chemistry.

UMEx Passive Samplers collect formaldehyde and other aldehydes in ppb and ppm range. Polypropylene units clip to worker's collar for personal sampling from 15 min to 8 hr, or are placed in appropriate location for indoor air sampling up to 24 hr for formaldehyde. No sample pump is needed. Each incorporates blank section in addition to active sampling section. On/off sliding cover starts and stops...

Read More »
Sample Pump provides portable mold sampling.
Fluid & Gas Flow Equipment

Sample Pump provides portable mold sampling.

QuickTake 15 Sample Pump provides constant flows from 5-15 l/min and is suitable for mold screening with Air-O-Cell(TM) Cassettes, WallChekÂ-® II, filter cassettes including microvacuum or remote media. Programmable timer allows user to select sample time presets or customize timer from 1-999 minutes. Intermittent and continuous run modes expand operation. Unit is portable for easy handheld...

Read More »
Portable Air Monitor includes downloading software.
Communication Systems & Equipment

Portable Air Monitor includes downloading software.

Microprocessor-based HAZ-DUST EPAM-5000, for environmental and indoor particulate monitoring, combines light-scattering dust monitoring with inline 37 mm filter cassette for concurrent gravimetric samples. It samples particles from 0.1 to 100 micrometers, using adjustable flow rate from 1.0 to 5.0 L/min, and reads particles from 0.001 to 20.0 mg/m3. Interchangeable size-selective sampling heads...

Read More »
Air Tester checks for diesel fumes.
Test & Measurement

Air Tester checks for diesel fumes.

DPM Cassette, with impactor, differentiates diesel particulate matter from other respirable dust based on particle size. It contains precision-jeweled impactor, impaction substrate, and quartz filter. Impactor screens out particles greater than 1.0 micrometer while particles less than 1.0 micrometer collect on filter. Samples are analyzed for total carbon content using EGA technique with...

Read More »
Personal Impactor collects coarse/fine/ultrafine particles.
Material Processing

Personal Impactor collects coarse/fine/ultrafine particles.

Sioutas Cascade Impactor separates and collects airborne particles in 5 size ranges: greater than 2.5 micron, 1.0-2.5 micron, 0.50-1.0 micron, 0.25-0.50 micron, and less than 0.25 micron. Unit is used with PTFE filters for minimal particle bounce and preservation of unstable compounds and clips to worker's collar or lapel for personal or area sampling. Optimal particle separation at specified...

Read More »
Air Sampling Pump features battery-powered operation.
Fluid & Gas Flow Equipment

Air Sampling Pump features battery-powered operation.

Designed to run at 1 L/min, Grab Air Sample Pump collects air into sample bags to assess exposure from airborne chemical hazards. It operates on 9 V battery, yielding up to 1,000 L volume. Recommended for sample bags with up to 10 L capacity, process is complete when bag is properly filled. Pump suits areas where leaks, spills, or other potentially hazardous events have occurred and concentration...

Read More »
Mold Sample Pump provides constant flows from 10-30 l/min.
Fluid & Gas Flow Equipment

Mold Sample Pump provides constant flows from 10-30 l/min.

Portable QuickTake 30 is suited for use with BioStage Impactors, BioCassette, spore trap cassettes such as VersaTrap or Air-O-Cell, and wall cavity samplers. Large keypad allows user to select preset sample time or customize timer up to 999 min. Front-mounted intake allows fast media setup, while intermittent and continuous run modes expand operation. Rechargeable lithium-ion battery pack...

Read More »
Sample Pump features low-noise design.
Fluid & Gas Flow Equipment

Sample Pump features low-noise design.

Model IAQ-3 provides constant flows from 5-3,250 ml/min for indoor air sampling applications. Manual programming is accomplished via 3-button keypad on pump. PC programmability allows delayed start, timed shutdown, intermittent sampling, and data management. Internal sensor measures flow directly and acts as secondary standard maintaining set flow. Pump is suited for use with sorbent tubes,...

Read More »
Color Change Wipes detect amount of lead on surfaces.
Cleaning Products & Equipment

Color Change Wipes detect amount of lead on surfaces.

Full Disclosure Wipes indicate presence of lead on skin and irregular surfaces such as safety glasses, steering wheels, and shoes. Product alerts worker to presence of lead residue following handwashing or cleaning regimens: user needs only to wipe surface, spray wipe with solutions, and observe color change. Yellow is negative for lead presence, and red is positive. Intensity of red bloom...

Read More »
Foil Grab Bags feature 4-layers to prevent permeation.
Agricultural & Farming Products

Foil Grab Bags feature 4-layers to prevent permeation.

Foil Grab Bags provide light and moisture protection for samples of low molecular weight compounds that are unstable in TedlarÂ-® sample bags. Inner surface is inert, minimizing absorption and adsorption of collected compounds. Evenly sealed seams make bags suitable for mailing or shipping samples to laboratory for analysis. Foil Grab Bags include stainless steel or polypropylene all-in-one...

Read More »
Passive Samplers utilize 2,4-DNPH chemistry.
Laboratory and Research Supplies and Equipment

Passive Samplers utilize 2,4-DNPH chemistry.

UMEx Passive Samplers collect formaldehyde and other aldehydes in ppb and ppm range. Polypropylene units clip to worker's collar for personal sampling from 15 min to 8 hr, or are placed in appropriate location for indoor air sampling up to 24 hr for formaldehyde. No sample pump is needed. Each incorporates blank section in addition to active sampling section. On/off sliding cover starts and stops...

Read More »
Sample Pump provides portable mold sampling.
Fluid & Gas Flow Equipment

Sample Pump provides portable mold sampling.

QuickTake 15 Sample Pump provides constant flows from 5-15 l/min and is suitable for mold screening with Air-O-Cell(TM) Cassettes, WallChekÂ-® II, filter cassettes including microvacuum or remote media. Programmable timer allows user to select sample time presets or customize timer from 1-999 minutes. Intermittent and continuous run modes expand operation. Unit is portable for easy handheld...

Read More »
Portable Air Monitor includes downloading software.
Communication Systems & Equipment

Portable Air Monitor includes downloading software.

Microprocessor-based HAZ-DUST EPAM-5000, for environmental and indoor particulate monitoring, combines light-scattering dust monitoring with inline 37 mm filter cassette for concurrent gravimetric samples. It samples particles from 0.1 to 100 micrometers, using adjustable flow rate from 1.0 to 5.0 L/min, and reads particles from 0.001 to 20.0 mg/m3. Interchangeable size-selective sampling heads...

Read More »
Air Tester checks for diesel fumes.
Test & Measurement

Air Tester checks for diesel fumes.

DPM Cassette, with impactor, differentiates diesel particulate matter from other respirable dust based on particle size. It contains precision-jeweled impactor, impaction substrate, and quartz filter. Impactor screens out particles greater than 1.0 micrometer while particles less than 1.0 micrometer collect on filter. Samples are analyzed for total carbon content using EGA technique with...

Read More »

All Topics